{"id":21080,"date":"2026-07-16T13:46:21","date_gmt":"2026-07-16T06:46:21","guid":{"rendered":"https:\/\/sonha.com\/?p=21080"},"modified":"2026-07-16T13:46:45","modified_gmt":"2026-07-16T06:46:45","slug":"tieu-chuan-en-16005-la-gi","status":"publish","type":"post","link":"https:\/\/sonha.com\/en\/what-is-en-16005\/","title":{"rendered":"What is EN 16005? Key safety requirements for automatic doors"},"content":{"rendered":"<p><em>A smooth-operating automatic door system does not necessarily mean it is a safe one. To minimize the risk of collisions, entrapment, and other accidents while ensuring reliable performance throughout its service life, manufacturers and installers must comply with strict technical requirements. Among these, EN 16005 is recognized as one of the most important safety standards for pedestrian automatic door systems. So, what does EN 16005 specify? Why has it become widely adopted around the world? And how do modern <a href=\"https:\/\/sonha.com\/en\/project-category\/?_project_filter_product_test=automatic-door\">automatic door solutions<\/a> meet these safety requirements? Join Sonha Auto as we explore these questions in the article below.<\/em><\/p>\n<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_74 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Content<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"Toggle Table of Content\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">Toggle<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #999;color:#999\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewBox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #999;color:#999\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewBox=\"0 0 24 24\" version=\"1.2\" baseProfile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1 ' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/sonha.com\/en\/what-is-en-16005\/#What_is_EN_16005\" >What is EN 16005?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/sonha.com\/en\/what-is-en-16005\/#Why_is_EN_16005_important\" >Why is EN 16005 important?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/sonha.com\/en\/what-is-en-16005\/#Key_safety_requirements_of_EN_16005\" >Key safety requirements of EN 16005<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/sonha.com\/en\/what-is-en-16005\/#Accurate_pedestrian_and_obstacle_detection\" >Accurate pedestrian and obstacle detection<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/sonha.com\/en\/what-is-en-16005\/#Control_of_opening_and_closing_force_and_speed\" >Control of opening and closing force and speed<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/sonha.com\/en\/what-is-en-16005\/#Automatic_stop_or_reverse_upon_obstacle_detection\" >Automatic stop or reverse upon obstacle detection<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/sonha.com\/en\/what-is-en-16005\/#Ensuring_emergency_egress\" >Ensuring emergency egress<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/sonha.com\/en\/what-is-en-16005\/#Periodic_inspection_and_maintenance\" >Periodic inspection and maintenance<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/sonha.com\/en\/what-is-en-16005\/#What_components_are_required_for_an_EN_16005-compliant_automatic_door_system\" >What components are required for an EN 16005-compliant automatic door system?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-10\" href=\"https:\/\/sonha.com\/en\/what-is-en-16005\/#NABCO_technology_is_designed_to_meet_international_safety_standards\" >NABCO technology is designed to meet international safety standards<\/a><\/li><\/ul><\/nav><\/div>\n<h2><span class=\"ez-toc-section\" id=\"What_is_EN_16005\"><\/span>What is EN 16005?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>A modern automatic door system must provide more than smooth operation\u2014it must also ensure the safety of every user. This is why EN 16005 was developed and has become one of Europe&#8217;s most important technical standards for pedestrian automatic doors.<\/p>\n<p>Published by the European Committee for Standardization (CEN) and officially effective since April 2013, EN 16005 specifies requirements for the design, installation, operation, inspection, and maintenance of automatic pedestrian doors to minimize the risk of collisions, entrapment, and other accidents during use.<\/p>\n<p>Today, EN 16005 is applied not only throughout Europe but is also widely referenced by automatic door manufacturers worldwide when developing products and safety solutions.<\/p>\n<figure id=\"attachment_21081\" aria-describedby=\"caption-attachment-21081\" style=\"width: 1200px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-21081 size-full\" title=\"How does EN 16005 apply to automatic doors?\" src=\"https:\/\/sonha.com\/wp-content\/uploads\/2026\/07\/tieu-chuan-en-16005-2.jpg\" alt=\"How does EN 16005 apply to automatic doors?\" width=\"1200\" height=\"674\" srcset=\"https:\/\/sonha.com\/wp-content\/uploads\/2026\/07\/tieu-chuan-en-16005-2.jpg 1200w, https:\/\/sonha.com\/wp-content\/uploads\/2026\/07\/tieu-chuan-en-16005-2-300x169.jpg 300w, https:\/\/sonha.com\/wp-content\/uploads\/2026\/07\/tieu-chuan-en-16005-2-1024x575.jpg 1024w, https:\/\/sonha.com\/wp-content\/uploads\/2026\/07\/tieu-chuan-en-16005-2-768x431.jpg 768w\" sizes=\"auto, (max-width: 1200px) 100vw, 1200px\" \/><figcaption id=\"caption-attachment-21081\" class=\"wp-caption-text\"><em>How does EN 16005 apply to automatic doors?<\/em><\/figcaption><\/figure>\n<h2><span class=\"ez-toc-section\" id=\"Why_is_EN_16005_important\"><\/span>Why is EN 16005 important?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>In facilities such as airports, hospitals, shopping malls, and office buildings, automatic doors may perform thousands of opening and closing cycles every day. Without proper design and control, risks such as doors closing while pedestrians are passing through, collisions with children or elderly users, or excessive closing force can occur.<\/p>\n<p>EN 16005 addresses these risks by defining specific requirements for:<\/p>\n<ul>\n<li>Pedestrian and obstacle detection<\/li>\n<li>Opening and closing force and speed control<\/li>\n<li>Automatic stopping or reversing when an obstacle is detected<\/li>\n<li>Emergency escape capability<\/li>\n<li>Periodic inspection and maintenance to maintain safety throughout the system&#8217;s service life<\/li>\n<\/ul>\n<p>Simply put, EN 16005 does not evaluate how fast a door opens, but rather how safely it operates.<\/p>\n<figure id=\"attachment_20587\" aria-describedby=\"caption-attachment-20587\" style=\"width: 1200px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-20587 size-full\" title=\"Ti\u00eau chu\u1ea9n EN 16005 gi\u00fap n\u00e2ng cao an to\u00e0n cho ng\u01b0\u1eddi s\u1eed d\u1ee5ng c\u1eeda t\u1ef1 \u0111\u1ed9ng\" src=\"https:\/\/sonha.com\/wp-content\/uploads\/2026\/06\/su-dung-cua-tu-dong-an-toan.jpg\" alt=\"Ti\u00eau chu\u1ea9n EN 16005 gi\u00fap n\u00e2ng cao an to\u00e0n cho ng\u01b0\u1eddi s\u1eed d\u1ee5ng c\u1eeda t\u1ef1 \u0111\u1ed9ng\" width=\"1200\" height=\"674\" srcset=\"https:\/\/sonha.com\/wp-content\/uploads\/2026\/06\/su-dung-cua-tu-dong-an-toan.jpg 1200w, https:\/\/sonha.com\/wp-content\/uploads\/2026\/06\/su-dung-cua-tu-dong-an-toan-300x169.jpg 300w, https:\/\/sonha.com\/wp-content\/uploads\/2026\/06\/su-dung-cua-tu-dong-an-toan-1024x575.jpg 1024w, https:\/\/sonha.com\/wp-content\/uploads\/2026\/06\/su-dung-cua-tu-dong-an-toan-768x431.jpg 768w\" sizes=\"auto, (max-width: 1200px) 100vw, 1200px\" \/><figcaption id=\"caption-attachment-20587\" class=\"wp-caption-text\"><em>EN 16005 enhances safety for automatic door users<\/em><\/figcaption><\/figure>\n<h2><span class=\"ez-toc-section\" id=\"Key_safety_requirements_of_EN_16005\"><\/span>Key safety requirements of EN 16005<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<h3><span class=\"ez-toc-section\" id=\"Accurate_pedestrian_and_obstacle_detection\"><\/span>Accurate pedestrian and obstacle detection<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>One of the most critical requirements of EN 16005 is that the door system must reliably detect people within hazardous areas. Therefore, modern automatic doors are typically equipped with activation sensors and safety sensors that continuously monitor the areas in front of and behind the door leaves. When a pedestrian or obstacle is detected, the system keeps the door open or prevents it from closing, significantly reducing the risk of impact.<\/p>\n<figure id=\"attachment_19834\" aria-describedby=\"caption-attachment-19834\" style=\"width: 1200px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-19834 size-full\" title=\"Automatic door safety sensors detect people within the operating zone\" src=\"https:\/\/sonha.com\/wp-content\/uploads\/2026\/04\/cam-bien-cua-tu-dong-nabco-2.jpg\" alt=\"Automatic door safety sensors detect people within the operating zone\" width=\"1200\" height=\"674\" srcset=\"https:\/\/sonha.com\/wp-content\/uploads\/2026\/04\/cam-bien-cua-tu-dong-nabco-2.jpg 1200w, https:\/\/sonha.com\/wp-content\/uploads\/2026\/04\/cam-bien-cua-tu-dong-nabco-2-300x169.jpg 300w, https:\/\/sonha.com\/wp-content\/uploads\/2026\/04\/cam-bien-cua-tu-dong-nabco-2-1024x575.jpg 1024w, https:\/\/sonha.com\/wp-content\/uploads\/2026\/04\/cam-bien-cua-tu-dong-nabco-2-768x431.jpg 768w\" sizes=\"auto, (max-width: 1200px) 100vw, 1200px\" \/><figcaption id=\"caption-attachment-19834\" class=\"wp-caption-text\"><em>Automatic door safety sensors detect people within the operating zone<\/em><\/figcaption><\/figure>\n<h3><span class=\"ez-toc-section\" id=\"Control_of_opening_and_closing_force_and_speed\"><\/span>Control of opening and closing force and speed<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>EN 16005 requires automatic doors to be configured with appropriate operating speeds and closing forces according to the door type, leaf weight, and installation environment. This requirement is particularly important in hospitals, schools, and shopping malls where children, elderly people, and wheelchair users are frequently present.<\/p>\n<p>Modern automatic door operators combine electric motors with electronic controllers to precisely regulate acceleration, deceleration, and operating force throughout each opening and closing cycle, ensuring both smooth operation and user safety.<\/p>\n<figure id=\"attachment_21076\" aria-describedby=\"caption-attachment-21076\" style=\"width: 1200px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-21076 size-full\" title=\"B\u1ed9 truy\u1ec1n \u0111\u1ed9ng c\u1eeda t\u1ef1 \u0111\u1ed9ng \u0111i\u1ec1u khi\u1ec3n l\u1ef1c v\u00e0 t\u1ed1c \u0111\u1ed9 v\u1eadn h\u00e0nh theo ti\u00eau chu\u1ea9n EN 16005\" src=\"https:\/\/sonha.com\/wp-content\/uploads\/2026\/07\/tieu-chuan-en-16005-1.jpg\" alt=\"B\u1ed9 truy\u1ec1n \u0111\u1ed9ng c\u1eeda t\u1ef1 \u0111\u1ed9ng \u0111i\u1ec1u khi\u1ec3n l\u1ef1c v\u00e0 t\u1ed1c \u0111\u1ed9 v\u1eadn h\u00e0nh theo ti\u00eau chu\u1ea9n EN 16005\" width=\"1200\" height=\"674\" srcset=\"https:\/\/sonha.com\/wp-content\/uploads\/2026\/07\/tieu-chuan-en-16005-1.jpg 1200w, https:\/\/sonha.com\/wp-content\/uploads\/2026\/07\/tieu-chuan-en-16005-1-300x169.jpg 300w, https:\/\/sonha.com\/wp-content\/uploads\/2026\/07\/tieu-chuan-en-16005-1-1024x575.jpg 1024w, https:\/\/sonha.com\/wp-content\/uploads\/2026\/07\/tieu-chuan-en-16005-1-768x431.jpg 768w\" sizes=\"auto, (max-width: 1200px) 100vw, 1200px\" \/><figcaption id=\"caption-attachment-21076\" class=\"wp-caption-text\"><em>Automatic door operators control operating force and speed in accordance with EN 16005<\/em><\/figcaption><\/figure>\n<h3><span class=\"ez-toc-section\" id=\"Automatic_stop_or_reverse_upon_obstacle_detection\"><\/span>Automatic stop or reverse upon obstacle detection<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>If an obstacle is detected while the door is closing, the system must immediately stop or reverse direction to prevent entrapment or collision. This is one of the most important safety functions of modern automatic door systems and is essential for buildings with high pedestrian traffic.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Ensuring_emergency_egress\"><\/span>Ensuring emergency egress<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>For public buildings, EN 16005 also requires automatic door systems to support safe evacuation during emergencies in accordance with the building&#8217;s emergency escape strategy.<\/p>\n<p>Depending on the door type and application, NABCO provides various evacuation solutions. For the NABCO GT-8300 automatic swing door, the system can be equipped with the Panic Breakout function, allowing the door leaf to swing open in both directions when sufficient force is applied, creating a wider escape route during emergencies.<\/p>\n<p>Meanwhile, the <a href=\"https:\/\/sonha.com\/en\/san-pham\/nabco-gt-1175-automatic-sliding-door-with-breakout-function\/\">NABCO GT-1175 Breakout<\/a> automatic sliding door is designed so that both the sliding panel and fixed sidelight can swing outward 90\u00b0 under an applied force of approximately 110 N, nearly doubling the clear opening width compared to a conventional sliding door. This significantly improves evacuation efficiency and facilitates the movement of stretchers, wheelchairs, and bulky equipment.<\/p>\n<p>Thanks to these solutions, the GT-8300 and GT-1175 are frequently selected for airports, hospitals, railway stations, shopping malls, exhibition centers, and other facilities where high safety standards and heavy pedestrian traffic are required.<\/p>\n<p><iframe loading=\"lazy\" title=\"YouTube video player\" src=\"https:\/\/www.youtube.com\/embed\/9h-R6biwGn0?si=dAE5LofJwugKDR0m\" width=\"800\" height=\"500\" frameborder=\"0\" allowfullscreen=\"allowfullscreen\"><span data-mce-type=\"bookmark\" style=\"display: inline-block; width: 0px; overflow: hidden; line-height: 0;\" class=\"mce_SELRES_start\">\ufeff<\/span><\/iframe><\/p>\n<p style=\"text-align: center;\"><em>The Breakout function expands the emergency escape opening on the NABCO GT-1175 automatic door<\/em><\/p>\n<h3><span class=\"ez-toc-section\" id=\"Periodic_inspection_and_maintenance\"><\/span>Periodic inspection and maintenance<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>The <a href=\"https:\/\/sonha.com\/en\/are-automatic-doors-safe\/\">safety of an automatic door<\/a> depends not only on the quality of its components but also on regular inspection and maintenance. EN 16005 recommends periodic inspections to ensure that sensors, motors, controllers, and safety devices continue to perform according to their design specifications.<\/p>\n<p>For high-traffic facilities such as airports and hospitals, scheduled maintenance also extends equipment lifespan while minimizing operational downtime.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"What_components_are_required_for_an_EN_16005-compliant_automatic_door_system\"><\/span>What components are required for an EN 16005-compliant automatic door system?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>To satisfy EN 16005 safety requirements, a modern automatic door system consists of more than just an operator. It includes:<\/p>\n<ul>\n<li>Automatic door operator<\/li>\n<li>Electric motor and gearbox<\/li>\n<li>Electronic controller<\/li>\n<li>Motion monitoring encoder<\/li>\n<li>Activation sensors<\/li>\n<li><a href=\"https:\/\/sonha.com\/en\/what-is-an-automatic-door-safety-sensor\/\">Safety sensors<\/a><\/li>\n<li>Electric lock (where required)<\/li>\n<li>Backup power supply or battery backup, depending on project requirements<\/li>\n<li>Access control devices and fire alarm interfaces where integration is required<\/li>\n<\/ul>\n<p>All of these components must be properly selected, configured, and calibrated to ensure the door operates in accordance with safety requirements.<\/p>\n<figure id=\"attachment_20801\" aria-describedby=\"caption-attachment-20801\" style=\"width: 1200px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-20801 size-full\" title=\"\u0110\u1ea7u \u0111\u1ecdc nh\u1eadn di\u1ec7n khu\u00f4n m\u1eb7t t\u00edch h\u1ee3p tr\u00ean c\u1eeda tr\u01b0\u1ee3t NABCO t\u1ea1i chung c\u01b0 Park 5\" src=\"https:\/\/sonha.com\/wp-content\/uploads\/2026\/06\/cua-truot-gap-break-out-nabco-tai-park-5-7.jpg\" alt=\"\u0110\u1ea7u \u0111\u1ecdc nh\u1eadn di\u1ec7n khu\u00f4n m\u1eb7t t\u00edch h\u1ee3p tr\u00ean c\u1eeda tr\u01b0\u1ee3t NABCO t\u1ea1i chung c\u01b0 Park 5\" width=\"1200\" height=\"674\" srcset=\"https:\/\/sonha.com\/wp-content\/uploads\/2026\/06\/cua-truot-gap-break-out-nabco-tai-park-5-7.jpg 1200w, https:\/\/sonha.com\/wp-content\/uploads\/2026\/06\/cua-truot-gap-break-out-nabco-tai-park-5-7-300x169.jpg 300w, https:\/\/sonha.com\/wp-content\/uploads\/2026\/06\/cua-truot-gap-break-out-nabco-tai-park-5-7-1024x575.jpg 1024w, https:\/\/sonha.com\/wp-content\/uploads\/2026\/06\/cua-truot-gap-break-out-nabco-tai-park-5-7-768x431.jpg 768w\" sizes=\"auto, (max-width: 1200px) 100vw, 1200px\" \/><figcaption id=\"caption-attachment-20801\" class=\"wp-caption-text\"><em>Facial recognition reader integrated with a NABCO automatic sliding door at Park 5 residential complex<\/em><\/figcaption><\/figure>\n<h2><span class=\"ez-toc-section\" id=\"NABCO_technology_is_designed_to_meet_international_safety_standards\"><\/span>NABCO technology is designed to meet international safety standards<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>As a Japanese automatic door manufacturer with more than 70 years of experience, NABCO has continuously enhanced safety through technological innovation across successive product generations. Many NABCO entrance solutions are developed in accordance with international technical standards such as JIS (Japan) while also incorporating safety principles widely referenced in standards such as EN 16005.<\/p>\n<p>Technologies including brushless DC motors, microprocessor-based controllers, <a href=\"https:\/\/sonha.com\/en\/automatic-door-can-technology\/\">CAN communication systems<\/a>, safety sensors, and advanced user protection functions enable NABCO automatic doors to operate reliably even in high-traffic environments such as airports, hospitals, shopping malls, and office buildings.<\/p>\n<p>With more than 20 years of partnership with NABCO, Sonha Auto not only supplies genuine equipment and replacement parts but also provides professional consultation, installation, and maintenance in accordance with the manufacturer&#8217;s recommendations, helping project owners maximize both system performance and operational safety.<\/p>\n<p><em><strong>&gt;&gt;&gt; See more: <a href=\"https:\/\/sonha.com\/en\/what-is-jis-a-4722\/\">What is JIS A 4722? Key safety criteria when selecting automatic doors<\/a><\/strong><\/em><\/p>\n<p><strong>Conclusion<\/strong><\/p>\n<p>EN 16005 is one of the most important standards for ensuring that automatic doors operate safely, reliably, and appropriately within their intended environments. Beyond selecting high-quality equipment, project owners should also consider the complete solution\u2014from sensors and controllers to professional installation and ongoing maintenance. With extensive experience installing thousands of automatic door systems across Vietnam, Sonha Auto is committed to delivering solutions that meet the technical and safety requirements of modern buildings, providing durable, efficient, and reliable automatic entrance systems throughout their service life.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>A smooth-operating automatic door system does not necessarily mean it is a safe one. To minimize the risk of collisions, entrapment, and other accidents while ensuring reliable performance throughout its service life, manufacturers and installers must comply with strict technical requirements. Among these, EN 16005 is recognized as one of the most important safety standards [&hellip;]<\/p>\n","protected":false},"author":6,"featured_media":21081,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[202,200],"tags":[],"class_list":["post-21080","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-news","category-professional-news"],"acf":[],"_links":{"self":[{"href":"https:\/\/sonha.com\/en\/wp-json\/wp\/v2\/posts\/21080","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/sonha.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/sonha.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/sonha.com\/en\/wp-json\/wp\/v2\/users\/6"}],"replies":[{"embeddable":true,"href":"https:\/\/sonha.com\/en\/wp-json\/wp\/v2\/comments?post=21080"}],"version-history":[{"count":1,"href":"https:\/\/sonha.com\/en\/wp-json\/wp\/v2\/posts\/21080\/revisions"}],"predecessor-version":[{"id":21083,"href":"https:\/\/sonha.com\/en\/wp-json\/wp\/v2\/posts\/21080\/revisions\/21083"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/sonha.com\/en\/wp-json\/wp\/v2\/media\/21081"}],"wp:attachment":[{"href":"https:\/\/sonha.com\/en\/wp-json\/wp\/v2\/media?parent=21080"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/sonha.com\/en\/wp-json\/wp\/v2\/categories?post=21080"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/sonha.com\/en\/wp-json\/wp\/v2\/tags?post=21080"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}