{"id":21107,"date":"2026-07-17T16:17:38","date_gmt":"2026-07-17T09:17:38","guid":{"rendered":"https:\/\/sonha.com\/?p=21107"},"modified":"2026-07-17T16:18:10","modified_gmt":"2026-07-17T09:18:10","slug":"cua-tu-dong-kiem-soat-nhiem-khuan","status":"publish","type":"post","link":"https:\/\/sonha.com\/en\/infection-control-automatic-doors\/","title":{"rendered":"Infection control automatic doors: A solution for hospitals, cleanrooms and food processing facilities"},"content":{"rendered":"<p><em>In environments that require stringent hygiene standards, such as hospitals, cleanrooms, and food processing plants, infection prevention is not solely dependent on sanitation procedures or HVAC systems. It begins at the entrance itself. As the primary passage for people, equipment, and airflow, entrances represent one of the highest-risk points for the transfer of microorganisms, airborne particles, and other contaminants. For this reason, infection control automatic doors have become an increasingly important component in the design of modern facilities. Beyond minimizing direct contact, these automatic door systems help maintain room pressure differentials, control airflow, and improve the overall effectiveness of the building&#8217;s infection prevention strategy.<\/em><\/p>\n<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_74 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Content<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"Toggle Table of Content\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">Toggle<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #999;color:#999\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewBox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #999;color:#999\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewBox=\"0 0 24 24\" version=\"1.2\" baseProfile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1 ' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/sonha.com\/en\/infection-control-automatic-doors\/#Infection_prevention_is_about_controlling_the_environment_not_just_cleaning\" >Infection prevention is about controlling the environment not just cleaning<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/sonha.com\/en\/infection-control-automatic-doors\/#What_requirements_must_automatic_doors_meet_in_hospitals\" >What requirements must automatic doors meet in hospitals?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/sonha.com\/en\/infection-control-automatic-doors\/#Technical_standards_related_to_hospital_and_cleanroom_doors\" >Technical standards related to hospital and cleanroom doors<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/sonha.com\/en\/infection-control-automatic-doors\/#EN_16005_%E2%80%93_Safety_standard_for_pedestrian_automatic_doors\" >EN 16005 &#8211; Safety standard for pedestrian automatic doors<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/sonha.com\/en\/infection-control-automatic-doors\/#ISO_14644_%E2%80%93_Cleanroom_standard\" >ISO 14644 &#8211; Cleanroom standard<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/sonha.com\/en\/infection-control-automatic-doors\/#GMP_and_HACCP_requirements_for_pharmaceutical_and_food_production\" >GMP and HACCP requirements for pharmaceutical and food production<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/sonha.com\/en\/infection-control-automatic-doors\/#How_do_infection_control_automatic_doors_help_prevent_contamination\" >How do infection control automatic doors help prevent contamination?<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/sonha.com\/en\/infection-control-automatic-doors\/#Minimize_direct_contact\" >Minimize direct contact<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/sonha.com\/en\/infection-control-automatic-doors\/#Help_maintain_room_pressure_and_airtightness\" >Help maintain room pressure and airtightness<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-10\" href=\"https:\/\/sonha.com\/en\/infection-control-automatic-doors\/#Reduce_unnecessary_air_exchange\" >Reduce unnecessary air exchange<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-11\" href=\"https:\/\/sonha.com\/en\/infection-control-automatic-doors\/#Giai_phap_cua_tu_dong_NABCO_cho_moi_truong_kiem_soat_nhiem_khuan\" >Gi\u1ea3i ph\u00e1p c\u1eeda t\u1ef1 \u0111\u1ed9ng NABCO cho m\u00f4i tr\u01b0\u1eddng ki\u1ec3m so\u00e1t nhi\u1ec5m khu\u1ea9n<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-12\" href=\"https:\/\/sonha.com\/en\/infection-control-automatic-doors\/#Sonha_Auto_provides_the_right_solution_for_every_project\" >Sonha Auto provides the right solution for every project<\/a><\/li><\/ul><\/nav><\/div>\n<h2><span class=\"ez-toc-section\" id=\"Infection_prevention_is_about_controlling_the_environment_not_just_cleaning\"><\/span>Infection prevention is about controlling the environment not just cleaning<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>When people think of infection prevention, they often associate it with surface disinfection, hand hygiene, or personal protective equipment (PPE). However, according to the Infection Prevention and Control (IPC) principles recommended by the World Health Organization (WHO), effective infection prevention is achieved through the integration of operational procedures, HVAC systems, traffic flow management, and facility design.<\/p>\n<p>Within this approach, entrance doors are considered an integral part of environmental control. They separate areas with different cleanliness classifications, minimize unwanted air exchange, and help maintain stable operating conditions in hospitals, cleanrooms, and food processing facilities.<\/p>\n<p>This is why infection control automatic doors are increasingly regarded as an essential component of an overall Infection Prevention and Control (IPC) strategy rather than simply automated entrance systems.<\/p>\n<figure id=\"attachment_21108\" aria-describedby=\"caption-attachment-21108\" style=\"width: 1200px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-21108 size-full\" title=\"Infection control automatic doors for hospitals and cleanrooms\" src=\"https:\/\/sonha.com\/wp-content\/uploads\/2026\/07\/cua-tu-dong-kiem-soat-nhiem-khuan-2.jpg\" alt=\"Infection control automatic doors for hospitals and cleanrooms\" width=\"1200\" height=\"674\" srcset=\"https:\/\/sonha.com\/wp-content\/uploads\/2026\/07\/cua-tu-dong-kiem-soat-nhiem-khuan-2.jpg 1200w, https:\/\/sonha.com\/wp-content\/uploads\/2026\/07\/cua-tu-dong-kiem-soat-nhiem-khuan-2-300x169.jpg 300w, https:\/\/sonha.com\/wp-content\/uploads\/2026\/07\/cua-tu-dong-kiem-soat-nhiem-khuan-2-1024x575.jpg 1024w, https:\/\/sonha.com\/wp-content\/uploads\/2026\/07\/cua-tu-dong-kiem-soat-nhiem-khuan-2-768x431.jpg 768w\" sizes=\"auto, (max-width: 1200px) 100vw, 1200px\" \/><figcaption id=\"caption-attachment-21108\" class=\"wp-caption-text\"><em>Infection control automatic doors for hospitals and cleanrooms<\/em><\/figcaption><\/figure>\n<h2><span class=\"ez-toc-section\" id=\"What_requirements_must_automatic_doors_meet_in_hospitals\"><\/span>What requirements must automatic doors meet in hospitals?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Not every <a href=\"https:\/\/sonha.com\/en\/hospital-door\/\">automatic door<\/a> system is suitable for healthcare environments. In addition to providing reliable opening and closing performance, hospital doors must satisfy a wide range of technical requirements to ensure safety while supporting infection prevention.<\/p>\n<table style=\"border-collapse: collapse; width: 100%;\">\n<tbody>\n<tr>\n<td style=\"width: 38.3317%; text-align: center;\"><strong>Requirement<\/strong><\/td>\n<td style=\"width: 61.6683%; text-align: center;\"><strong>\u00a0Purpose<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 38.3317%;\">Minimize physical contact<\/td>\n<td style=\"width: 61.6683%;\">Reduce the risk of cross-contamination through door handles<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 38.3317%;\">High airtightness<\/td>\n<td style=\"width: 61.6683%;\">High airtightness<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 38.3317%;\">Quiet operation<\/td>\n<td style=\"width: 61.6683%;\">Reduce noise in treatment areas and operating rooms<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 38.3317%;\">Safe operation<\/td>\n<td style=\"width: 61.6683%;\">Protect patients, healthcare staff, and medical carts<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 38.3317%;\">Continuous operation<\/td>\n<td style=\"width: 61.6683%;\">Support 24\/7 high-frequency use<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 38.3317%;\">Easy to clean<\/td>\n<td style=\"width: 61.6683%;\">Minimize gaps and simplify cleaning and disinfection<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 38.3317%;\">System integration<\/td>\n<td style=\"width: 61.6683%;\">Connect with access control, fire alarm, and Building Management Systems (BMS)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>These are also among the key criteria considered by project owners when selecting automatic door solutions for hospitals, cleanrooms, and other hygiene-critical environments.<\/p>\n<figure id=\"attachment_21104\" aria-describedby=\"caption-attachment-21104\" style=\"width: 1200px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-21104 size-full\" title=\"C\u1eeda t\u1ef1 \u0111\u1ed9ng h\u1ed7 tr\u1ee3 ki\u1ec3m so\u00e1t lu\u1ed3ng kh\u00f4ng kh\u00ed trong b\u1ec7nh vi\u1ec7n\" src=\"https:\/\/sonha.com\/wp-content\/uploads\/2026\/07\/cua-tu-dong-kiem-soat-nhiem-khuan-1.jpg\" alt=\"C\u1eeda t\u1ef1 \u0111\u1ed9ng h\u1ed7 tr\u1ee3 ki\u1ec3m so\u00e1t lu\u1ed3ng kh\u00f4ng kh\u00ed trong b\u1ec7nh vi\u1ec7n\" width=\"1200\" height=\"674\" srcset=\"https:\/\/sonha.com\/wp-content\/uploads\/2026\/07\/cua-tu-dong-kiem-soat-nhiem-khuan-1.jpg 1200w, https:\/\/sonha.com\/wp-content\/uploads\/2026\/07\/cua-tu-dong-kiem-soat-nhiem-khuan-1-300x169.jpg 300w, https:\/\/sonha.com\/wp-content\/uploads\/2026\/07\/cua-tu-dong-kiem-soat-nhiem-khuan-1-1024x575.jpg 1024w, https:\/\/sonha.com\/wp-content\/uploads\/2026\/07\/cua-tu-dong-kiem-soat-nhiem-khuan-1-768x431.jpg 768w\" sizes=\"auto, (max-width: 1200px) 100vw, 1200px\" \/><figcaption id=\"caption-attachment-21104\" class=\"wp-caption-text\"><em>Automatic doors help control airflow in hospitals<\/em><\/figcaption><\/figure>\n<h2><span class=\"ez-toc-section\" id=\"Technical_standards_related_to_hospital_and_cleanroom_doors\"><\/span>Technical standards related to hospital and cleanroom doors<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>To better understand these requirements, it is important to recognize that <a href=\"https:\/\/sonha.com\/en\/hospital-door\/\">hospital and cleanroom doors<\/a> are evaluated according to internationally recognized technical standards rather than visual appearance alone.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"EN_16005_%E2%80%93_Safety_standard_for_pedestrian_automatic_doors\"><\/span>EN 16005 &#8211; Safety standard for pedestrian automatic doors<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p><a href=\"https:\/\/sonha.com\/en\/what-is-en-16005\/\">EN 16005<\/a>\u00a0is the European safety standard governing automatic pedestrian doors. It specifies requirements for operating force, sensor detection zones, obstacle detection, and user protection.<\/p>\n<p>Today, EN 16005 serves as one of the primary international references used by many automatic door manufacturers during product development.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"ISO_14644_%E2%80%93_Cleanroom_standard\"><\/span>ISO 14644 &#8211; Cleanroom standard<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>ISO 14644 defines cleanroom air cleanliness classifications based on the allowable concentration of airborne particles. Although the standard does not prescribe specific door designs, door systems must support cleanroom performance by minimizing air leakage and reducing particle generation during operation.<\/p>\n<figure id=\"attachment_21076\" aria-describedby=\"caption-attachment-21076\" style=\"width: 1200px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-21076 size-full\" title=\"Ti\u00eau chu\u1ea9n EN 16005 cho c\u1eeda t\u1ef1 \u0111\u1ed9ng \u0111\u1ea3m b\u1ea3o an to\u00e0n khi v\u1eadn h\u00e0nh\" src=\"https:\/\/sonha.com\/wp-content\/uploads\/2026\/07\/tieu-chuan-en-16005-1.jpg\" alt=\"Ti\u00eau chu\u1ea9n EN 16005 cho c\u1eeda t\u1ef1 \u0111\u1ed9ng \u0111\u1ea3m b\u1ea3o an to\u00e0n khi v\u1eadn h\u00e0nh\" width=\"1200\" height=\"674\" srcset=\"https:\/\/sonha.com\/wp-content\/uploads\/2026\/07\/tieu-chuan-en-16005-1.jpg 1200w, https:\/\/sonha.com\/wp-content\/uploads\/2026\/07\/tieu-chuan-en-16005-1-300x169.jpg 300w, https:\/\/sonha.com\/wp-content\/uploads\/2026\/07\/tieu-chuan-en-16005-1-1024x575.jpg 1024w, https:\/\/sonha.com\/wp-content\/uploads\/2026\/07\/tieu-chuan-en-16005-1-768x431.jpg 768w\" sizes=\"auto, (max-width: 1200px) 100vw, 1200px\" \/><figcaption id=\"caption-attachment-21076\" class=\"wp-caption-text\"><em>EN 16005 helps ensure safe automatic door operation<\/em><\/figcaption><\/figure>\n<h3><span class=\"ez-toc-section\" id=\"GMP_and_HACCP_requirements_for_pharmaceutical_and_food_production\"><\/span>GMP and HACCP requirements for pharmaceutical and food production<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>In pharmaceutical manufacturing facilities, doors must comply with Good Manufacturing Practice (GMP) requirements for hygiene, cleanability, and environmental control. For food processing plants, Hazard Analysis and Critical Control Points (HACCP) identifies entrance areas as critical control points where cross-contamination risks must be effectively managed.<\/p>\n<p>These standards demonstrate that automatic doors are not merely mechanical systems they are integral components of quality assurance and safety management within highly controlled environments.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"How_do_infection_control_automatic_doors_help_prevent_contamination\"><\/span>How do infection control automatic doors help prevent contamination?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Infection control automatic doors contribute to infection prevention through the combination of advanced sensor technology, airtight door construction, and automated operation. Together, these features help reduce the risk of cross-contamination while supporting environmental control in areas with stringent hygiene requirements.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Minimize_direct_contact\"><\/span>Minimize direct contact<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Door handles are among the most frequently touched surfaces in hospitals. When multiple users repeatedly touch the same surface, the risk of cross-contamination increases significantly unless frequent disinfection is performed.<\/p>\n<p>Automatic doors use sensors or touchless activation devices, such as non-contact infrared switches, to open automatically when a person approaches, helping reduce direct contact with the door surface. The system can also be integrated with infrared sensors, touchless push buttons, or access control systems to meet the specific operational requirements of different functional areas.<\/p>\n<figure id=\"attachment_20831\" aria-describedby=\"caption-attachment-20831\" style=\"width: 1200px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-20831 size-full\" title=\"C\u1eeda t\u1ef1 \u0111\u1ed9ng ki\u1ec3m so\u00e1t nhi\u1ec5m khu\u1ea9n t\u00edch h\u1ee3p c\u00f4ng t\u1eafc h\u1ed3ng ngo\u1ea1i kh\u00f4ng ch\u1ea1m cho m\u00f4i tr\u01b0\u1eddng b\u1ec7nh vi\u1ec7n\" src=\"https:\/\/sonha.com\/wp-content\/uploads\/2026\/06\/cua-benh-vien-198-5.jpg\" alt=\"C\u1eeda t\u1ef1 \u0111\u1ed9ng ki\u1ec3m so\u00e1t nhi\u1ec5m khu\u1ea9n t\u00edch h\u1ee3p c\u00f4ng t\u1eafc h\u1ed3ng ngo\u1ea1i kh\u00f4ng ch\u1ea1m cho m\u00f4i tr\u01b0\u1eddng b\u1ec7nh vi\u1ec7n\" width=\"1200\" height=\"674\" srcset=\"https:\/\/sonha.com\/wp-content\/uploads\/2026\/06\/cua-benh-vien-198-5.jpg 1200w, https:\/\/sonha.com\/wp-content\/uploads\/2026\/06\/cua-benh-vien-198-5-300x169.jpg 300w, https:\/\/sonha.com\/wp-content\/uploads\/2026\/06\/cua-benh-vien-198-5-1024x575.jpg 1024w, https:\/\/sonha.com\/wp-content\/uploads\/2026\/06\/cua-benh-vien-198-5-768x431.jpg 768w\" sizes=\"auto, (max-width: 1200px) 100vw, 1200px\" \/><figcaption id=\"caption-attachment-20831\" class=\"wp-caption-text\"><em>Infection control automatic doors integrated with touchless infrared switches for hospital environments<\/em><\/figcaption><\/figure>\n<h3><span class=\"ez-toc-section\" id=\"Help_maintain_room_pressure_and_airtightness\"><\/span>Help maintain room pressure and airtightness<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>For operating theatres, isolation rooms, intensive care units (ICUs), and cleanrooms, maintaining positive or negative room pressure is essential for controlling airflow direction and preventing the spread of airborne contaminants.<\/p>\n<p>If a door is not sufficiently airtight or remains open longer than necessary, pressure differentials may be compromised, reducing the effectiveness of the entire HVAC system.<\/p>\n<p>For this reason, automatic airtight doors typically incorporate a compression sealing mechanism together with perimeter gaskets. Once fully closed, the door leaf is pressed firmly against the frame to minimize air leakage, helping maintain the environmental conditions required for operating rooms and cleanrooms.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Reduce_unnecessary_air_exchange\"><\/span>Reduce unnecessary air exchange<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>A properly configured automatic door opens only when necessary and closes immediately after people or carts have passed through. This minimizes the loss of conditioned air, reduces the workload on the building&#8217;s HVAC system, and helps maintain a stable environment within controlled areas.<\/p>\n<figure id=\"attachment_14111\" aria-describedby=\"caption-attachment-14111\" style=\"width: 1200px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-14111 size-full\" title=\"C\u1eeda t\u1ef1 \u0111\u1ed9ng NABCO t\u1ea1i B\u1ec7nh vi\u1ec7n Nhi Trung \u01b0\u01a1ng h\u1ed7 tr\u1ee3 ki\u1ec3m so\u00e1t nhi\u1ec5m khu\u1ea9n\" src=\"https:\/\/sonha.com\/wp-content\/uploads\/2025\/07\/benh-vien-nhi-trung-uong-4.jpg\" alt=\"C\u1eeda t\u1ef1 \u0111\u1ed9ng NABCO t\u1ea1i B\u1ec7nh vi\u1ec7n Nhi Trung \u01b0\u01a1ng h\u1ed7 tr\u1ee3 ki\u1ec3m so\u00e1t nhi\u1ec5m khu\u1ea9n\" width=\"1200\" height=\"674\" srcset=\"https:\/\/sonha.com\/wp-content\/uploads\/2025\/07\/benh-vien-nhi-trung-uong-4.jpg 1200w, https:\/\/sonha.com\/wp-content\/uploads\/2025\/07\/benh-vien-nhi-trung-uong-4-300x169.jpg 300w, https:\/\/sonha.com\/wp-content\/uploads\/2025\/07\/benh-vien-nhi-trung-uong-4-1024x575.jpg 1024w, https:\/\/sonha.com\/wp-content\/uploads\/2025\/07\/benh-vien-nhi-trung-uong-4-768x431.jpg 768w\" sizes=\"auto, (max-width: 1200px) 100vw, 1200px\" \/><figcaption id=\"caption-attachment-14111\" class=\"wp-caption-text\"><em>NABCO automatic doors at the <a href=\"https:\/\/sonha.com\/en\/project\/vietnam-national-childrens-hospital\/\">National Children&#8217;s Hospital<\/a> support infection prevention and environmental control<\/em><\/figcaption><\/figure>\n<h2><span class=\"ez-toc-section\" id=\"Giai_phap_cua_tu_dong_NABCO_cho_moi_truong_kiem_soat_nhiem_khuan\"><\/span>Gi\u1ea3i ph\u00e1p c\u1eeda t\u1ef1 \u0111\u1ed9ng NABCO cho m\u00f4i tr\u01b0\u1eddng ki\u1ec3m so\u00e1t nhi\u1ec5m khu\u1ea9n<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>As a Japanese automatic door manufacturer with nearly 70 years of experience, NABCO offers a comprehensive range of infection control automatic doors designed for hospitals, cleanrooms, and other facilities with stringent hygiene requirements. These door systems are engineered to help maintain airtightness, minimize physical contact, and deliver reliable performance under continuous operation.<\/p>\n<p><a href=\"https:\/\/sonha.com\/en\/hospital-door\/?_brand=nabco-japan\">NABCO&#8217;s automatic airtight door<\/a> systems incorporate an Automatic Compression Mechanism together with perimeter sealing gaskets. Once fully closed, the door leaf is compressed tightly against the frame to reduce air leakage, helping maintain pressure differentials and improve infection control performance in operating theatres, cleanrooms, and other critical healthcare environments.<\/p>\n<p>In addition, NABCO offers a variety of supporting technologies, including touchless activation sensors, the NATRUS intelligent sensor system, <a href=\"https:\/\/sonha.com\/en\/san-pham\/nabco-hds-a5-push-button-switch\/\">HDS-A5 control switches<\/a>, and seamless integration with access control, fire alarm, and Building Management Systems (BMS).<\/p>\n<p>These technologies help minimize unnecessary door activations, optimize traffic flow, and enhance operational safety.<\/p>\n<p>NABCO solutions are widely installed in hospitals, cleanrooms, pharmaceutical manufacturing plants, and food processing facilities throughout Japan and many other countries, delivering reliable performance even in high-traffic environments.<\/p>\n<figure id=\"attachment_20495\" aria-describedby=\"caption-attachment-20495\" style=\"width: 1200px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-20495 size-full\" title=\"Gi\u1ea3i ph\u00e1p c\u1eeda t\u1ef1 \u0111\u1ed9ng ki\u1ec3m so\u00e1t nhi\u1ec5m khu\u1ea9n NABCO\" src=\"https:\/\/sonha.com\/wp-content\/uploads\/2026\/06\/cau-tao-cua-kin-khi-nabco-nax.jpg\" alt=\"Gi\u1ea3i ph\u00e1p c\u1eeda t\u1ef1 \u0111\u1ed9ng ki\u1ec3m so\u00e1t nhi\u1ec5m khu\u1ea9n NABCO\" width=\"1200\" height=\"674\" srcset=\"https:\/\/sonha.com\/wp-content\/uploads\/2026\/06\/cau-tao-cua-kin-khi-nabco-nax.jpg 1200w, https:\/\/sonha.com\/wp-content\/uploads\/2026\/06\/cau-tao-cua-kin-khi-nabco-nax-300x169.jpg 300w, https:\/\/sonha.com\/wp-content\/uploads\/2026\/06\/cau-tao-cua-kin-khi-nabco-nax-1024x575.jpg 1024w, https:\/\/sonha.com\/wp-content\/uploads\/2026\/06\/cau-tao-cua-kin-khi-nabco-nax-768x431.jpg 768w\" sizes=\"auto, (max-width: 1200px) 100vw, 1200px\" \/><figcaption id=\"caption-attachment-20495\" class=\"wp-caption-text\"><em>NABCO infection control automatic door solutions<\/em><\/figcaption><\/figure>\n<p><em><strong>&gt;&gt;&gt; See more: <a href=\"https:\/\/sonha.com\/en\/why-do-operating-rooms-need-airtight-doors\/\">Why do operating rooms need airtight doors? A contamination control solution for modern hospitals<\/a><\/strong><\/em><\/p>\n<h2><span class=\"ez-toc-section\" id=\"Sonha_Auto_provides_the_right_solution_for_every_project\"><\/span>Sonha Auto provides the right solution for every project<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>The effectiveness of infection control automatic doors depends not only on the quality of the equipment but also on selecting the appropriate solution for each application. Every project has unique requirements regarding cleanliness classification, traffic volume, safety standards, and environmental conditions. Therefore, the door system should be properly specified from the outset to ensure it performs its intended function effectively.<\/p>\n<p>With more than 20 years as NABCO&#8217;s official partner in Vietnam, Sonha Auto has delivered <a href=\"https:\/\/sonha.com\/en\/project-category\/?_project_filter_field=hospitals\">automatic door solutions for hospitals<\/a>, operating theatres, cleanrooms, and food processing facilities across the country.<\/p>\n<p>From on-site surveys and system configuration to installation and preventive maintenance in accordance with NABCO&#8217;s technical standards, every door system is designed to meet the project&#8217;s requirements for airtightness, operational safety, and long-term reliability.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>In environments that require stringent hygiene standards, such as hospitals, cleanrooms, and food processing plants, infection prevention is not solely dependent on sanitation procedures or HVAC systems. It begins at the entrance itself. As the primary passage for people, equipment, and airflow, entrances represent one of the highest-risk points for the transfer of microorganisms, airborne [&hellip;]<\/p>\n","protected":false},"author":6,"featured_media":21108,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[202,200],"tags":[],"class_list":["post-21107","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-news","category-professional-news"],"acf":[],"_links":{"self":[{"href":"https:\/\/sonha.com\/en\/wp-json\/wp\/v2\/posts\/21107","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/sonha.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/sonha.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/sonha.com\/en\/wp-json\/wp\/v2\/users\/6"}],"replies":[{"embeddable":true,"href":"https:\/\/sonha.com\/en\/wp-json\/wp\/v2\/comments?post=21107"}],"version-history":[{"count":2,"href":"https:\/\/sonha.com\/en\/wp-json\/wp\/v2\/posts\/21107\/revisions"}],"predecessor-version":[{"id":21111,"href":"https:\/\/sonha.com\/en\/wp-json\/wp\/v2\/posts\/21107\/revisions\/21111"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/sonha.com\/en\/wp-json\/wp\/v2\/media\/21108"}],"wp:attachment":[{"href":"https:\/\/sonha.com\/en\/wp-json\/wp\/v2\/media?parent=21107"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/sonha.com\/en\/wp-json\/wp\/v2\/categories?post=21107"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/sonha.com\/en\/wp-json\/wp\/v2\/tags?post=21107"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}