Automatic door motor power and how to choose the right load capacity for each project

During operation, many automatic door systems encounter issues such as weak movement, vibration, jerking, unusual noise, or rapid motor deterioration after a period of use. In reality, the cause is not only related to equipment quality but is also directly associated with selecting the wrong automatic door motor power from the beginning. For projects with high traffic frequency such as hospitals, shopping malls, or hotels, accurately calculating door weight, operating frequency, and motor technical specifications is extremely important to ensure stable and durable door operation over the long term. So, how is automatic door motor power calculated, and which specifications should be carefully considered when selecting a motor? Let Sonha Auto explore the details in the article below.

Why is automatic door motor power important?

In an automatic door system, the motor or door operator is the component responsible for carrying the load and maintaining the movement of the entire door leaf. Therefore, automatic door motor power directly affects the operational stability and lifespan of the entire system.

If the selected motor is too small compared to the actual door load, the motor will constantly operate under overload conditions. As a result, the door may experience slow opening and closing, vibration, overheating, or controller board errors after a short period of operation. In addition to affecting motor durability, excessive load also increases pressure on the sliding rail, rollers, and the entire mechanical operating system.

On the contrary, many projects tend to choose oversized motors with the assumption that “higher capacity means better durability.” However, selecting an excessively large automatic door motor not only increases investment costs but also wastes power and makes operation optimization more difficult for smaller door systems. In practice, a stable automatic door system does not depend on using the most powerful motor, but on the synchronization between the motor, door load, controller, sliding rail, and actual operating conditions of the project.

Công suất motor cửa tự động và khả năng vận hành ổn định của hệ cửa tự động
Automatic door motor power and stable operation of automatic door systems

How is automatic door motor power calculated?

Many people assume that motor selection can be based solely on door dimensions. However, in actual engineering practice, selecting an automatic door motor must be calculated based on multiple factors.

Automatic door weight

This is the most important factor when selecting a motor. Door weight includes not only the glass panels but also aluminum frames, stainless steel frames, accessories, and transmission mechanisms. For large door systems or doors using thick glass, the actual load is often significantly higher than common estimates.

Door opening and closing frequency

A small office door system may only operate a few hundred times per day, while doors at airports, hospitals, or shopping malls may operate continuously almost nonstop. The higher the usage frequency, the greater the requirement for motor durability and stable load performance.

Actual operating environment

Projects exposed to strong winds, high humidity, or dust typically require motors with more stable operating capability and better synchronization with sensor systems to minimize signal errors during operation.

Type of automatic door

Each door type has different load requirements, such as:

This is why selecting an automatic door motor always requires separate calculations for each project model rather than applying a fixed configuration.

Các yếu tố ảnh hưởng đến công suất motor cửa tự động
Factors affecting automatic door motor power

Common automatic door motor power chart today

Motor power Door load capacity Common applications
75W – 100W 60 – 100kg/door leaf Small offices, showrooms
100W – 150W 100 – 150kg/door leaf Shops, hotels
150W – 200W 150 – 200kg/door leaf Hospitals, shopping malls, airports
Above 200W Over 200kg/door leaf Heavy-duty automatic door systems

However, the automatic door motor power chart above is only a basic reference. In many cases, two door systems with the same load capacity but different traffic volumes still require completely different motor configurations.

For example, a 120kg door system at a small showroom has very different requirements compared to a 120kg door at a shopping mall operating continuously all day. Therefore, motor selection cannot rely solely on load capacity but must also evaluate the overall actual operating conditions.

Important automatic door motor specifications technicians should pay attention to

Besides power output, technicians must clearly understand important automatic door motor specifications to avoid unstable door operation after installation.

Torque

Torque determines the motor’s ability to pull the load and maintain stable movement when the door starts opening or closing. Motors with low torque are more likely to lose pulling force during continuous operation or when encountering high resistance, especially in projects with large doors and heavy traffic flow.

Duty cycle – Continuous operating capability

This is a very important specification but is often overlooked. Duty cycle reflects the motor’s ability to operate continuously for long periods while maintaining stable performance. If a residential-grade motor is used in high-traffic projects such as hospitals or shopping malls, the motor will quickly overheat and its lifespan will decrease even when the load has not exceeded the limit.

Tải trọng cửa ảnh hưởng trực tiếp đến lựa chọn motor
Door load directly affects motor selection

Opening and closing speed and damping capability

A faster door is not always better. For hotels, premium offices, or hospitals, opening and closing speed must be optimized to ensure smooth operation, reduce impact, and improve user experience. A high-quality motor typically offers better acceleration and deceleration control, helping the door move smoothly and reducing vibration during operation.

Synchronization capability between controller and sensors

Even if the motor itself is high quality, slow controller response or unsynchronized sensors can still cause unstable operation. This is why modern automatic door systems focus not only on motor power but also on signal communication and synchronized operation between the motor, sensors, and control board.

Common mistakes when selecting automatic door motors

One of the most common mistakes when selecting automatic door motor power is focusing only on motor price while ignoring the actual door load and project operating conditions.

Many door systems use low-cost motors but soon develop issues such as vibration, overheating, or reduced operating speed after a short period of use. In addition, incorrect automatic door load calculations also cause many systems to deteriorate quickly because the motor constantly operates under overload conditions.

Furthermore, many high-traffic projects still use residential-grade motors instead of specialized motors designed for heavy-duty automatic door systems, significantly reducing equipment lifespan.

Motor cửa tự động vận hành liên tục tại trung tâm thương mại Aeon Mall
Automatic door motor operating continuously at Aeon Mall shopping center

Why are NABCO automatic door motors highly rated?

In the automatic door industry, NABCO is highly regarded not only for its motors but also for its overall synchronized operating system design philosophy. Instead of focusing solely on increasing pulling power, NABCO Japanese automatic door motors are designed to maintain stable load performance and optimize long-term operation. The motor system is synchronized with the controller, sliding rail, rollers, and sensors to reduce vibration, minimize mechanical wear, and maintain stable movement even in environments with extremely high operating frequency.

One of NABCO’s major advantages is the application of CAN technology in the NET-DS controller system. This technology allows the motor, sensors, and controller to continuously exchange real-time data through the same communication system. As a result, the door can respond more accurately to actual movement, reduce the risk of signal errors, and maintain stable synchronization throughout operation.

This is also why many NABCO door systems at airports, hospitals, and shopping malls continue to maintain stable operation even after long periods of continuous use.

Sonha Auto tư vấn lựa chọn motor cửa tự động phù hợp cho từng công trình
Sonha Auto provides consultation on selecting the right automatic door motor for each project

>>> See more: How long does an automatic door motor last? How to extend its lifespan and when to replace it

Conclusion

Selecting the correct automatic door motor power not only affects opening and closing performance but also directly determines the stability, durability, and lifespan of the entire door system during long-term operation. For high-traffic projects such as hospitals, shopping malls, or hotels, the motor must be calculated and synchronized according to door load, operating frequency, and actual usage conditions to minimize vibration, overload, and future operational issues.

With more than 20 years of experience implementing automatic door systems in major projects, Sonha Auto possesses a technical team trained by Japanese experts, directly surveying and consulting the most suitable motor configuration for each door system to ensure stable operation, long-term durability, and optimized operating costs.

Contact Sonha Auto for consultation on selecting the most suitable automatic door motor for your actual project model!

Related news

What makes NABCO automatic doors for large-scale projects special that leads investors to prioritize them?
2506.2026
25/06/2026
News
What makes NABCO automatic doors for large-scale projects special that leads investors to prioritize them?

In high-traffic projects such as hospitals, airports, or shopping centers, automatic door systems are not merely entry devices; they are a core link that determines customer experience and building operational efficiency. NABCO automatic doors for large-scale projects are trusted by many projects around the world and in Vietnam not by chance, but thanks to their […]

Should you choose Japanese automatic doors or Chinese automatic doors? A detailed comparison
2406.2026
24/06/2026
News
Should you choose Japanese automatic doors or Chinese automatic doors? A detailed comparison

When selecting automatic doors, one should not focus solely on the initial purchase price. What investors need to consider is which system offers more stable operation, fewer faults, and optimal long-term cost efficiency: Japanese automatic doors or Chinese automatic doors. In reality, this is a matter directly related to durability, safety, maintenance costs, and long-term […]

Sonha welcomes senior leadership delegation from NABCO Japan on the 20th anniversary of the strategic partnership
2306.2026
23/06/2026
News
Sonha welcomes senior leadership delegation from NABCO Japan on the 20th anniversary of the strategic partnership

On June 17, 2026, Sonha Joint Stock Company was honored to welcome a senior leadership delegation from NABCO Japan and Nabtesco Corporation to its headquarters. The visit took place on the occasion of the 20th anniversary of the strategic partnership between Sonha and NABCO. This special event not only marked two decades of strategic cooperation […]

Automatic doors do not open? Common causes and quick solutions
2306.2026
23/06/2026
News
Automatic doors do not open? Common causes and quick solutions

Today, automatic doors bring convenience and professionalism to modern buildings. However, after a period of use, the system may encounter faults that cause automatic doors do not open, directly affecting operational efficiency and user experience. The cause of this issue is not limited to the motor but may also be related to the power supply, […]